Made with this code and graphviz.
Friday, December 30, 2011
Friday, December 2, 2011
Calibration: As good as it's gonna get
BGPS vs BGPSv2 in Cyg X
BGPS vs BGPSv2 in IRDC1 (Rathborne)
BGPS vs BGPSv2 in l=44 (comparison is SIMBA, not MAMBO)
Tuesday, November 15, 2011
Calibration Offsets Revisited
The agreement with Motte et al 2007 is now perfect with a vertical ADDITIVE offset instead of the annoying multiplicative offset. An additive offset can trivially be accounted for by a spatial transfer function. As is evident in the difference images, the MAMBO data appears to sit on a plateau.
Cygnus X:
BGPSV1:
BGPSV2:
Cygnus X:
BGPSV1:
BGPSV2:
Monday, August 29, 2011
Bolocat v1-v2 comparison with new calibration
I re-examined the Bolocat data on l351 after re-running the pipeline with the new calibration curve. The change wasn't all that great. See this post for a brief description of the procedure.
In the data below, I've fit the residuals as a function of v1.0.2 flux density in an aperture (source mask) with a line. The slope of the line should ideally be zero - that would indicate a multiplicative offset is an acceptable correction.
Nicely, in the 40" aperture case, I see no reason to exclude the m=0 case. For the most reliable data - the 13pca - the slope is rather small and the "correction factor" is disturbingly close to what we recommended (1.5). We have no right to be that lucky...
...and so perhaps wer are not. The source mask includes more area and therefore is more sensitive to extended flux recovery. The slopes are not consistent with 0 - just look at the data above and below 2 Jy to see that there is a difference. The multiplicative correction of 1.5 is decent for a pretty wide range of flux densities, but is inadequate for the brightest sources. This is somewhat interesting... it implies that the brightest sources also lie on the highest backgrounds.
You might note that the brightest source has a smaller correction factor in both apertures. It's not clear why that is the case, but I don't think it's enough to call it a trend yet - wait for the full 8000-source comparison first.
Why is there so much scatter? Not entirely clear, but the scatter is primarily at low S/N.
Here are the same for all of the data reduced up to this point:
Friday, August 26, 2011
Final calibration curves (yeah... sure)
I've finished rederiving the calibration curves self-consistently. These will now be applied to the data....
Thursday, August 25, 2011
V1 vs V2: Calibration Curves
Why did we find a factor ~1.8 in the previous post? Well, for starters we used a calibration curve that was based off of 'masking' and other tricky techniques.
The calibration curves below are the first ever produced self-consistently, i.e. using the EXACT same pipeline with the EXACT same parameters as the science data. No hacks were needed to produce these*. The recovered Volts/Jy are substantially higher than BGPSv1 and ALSO higher than the curve used about a year ago in an attempt to explain the v1 flux discrepancy.
Remember that a higher calibration curve means a LOWER recovered flux. I haven't finished the check, but odds are pretty good that applying these self-consistent cal curves will reduce the v2 data to be about 1.5.
The calibration curves below are the first ever produced self-consistently, i.e. using the EXACT same pipeline with the EXACT same parameters as the science data. No hacks were needed to produce these*. The recovered Volts/Jy are substantially higher than BGPSv1 and ALSO higher than the curve used about a year ago in an attempt to explain the v1 flux discrepancy.
Remember that a higher calibration curve means a LOWER recovered flux. I haven't finished the check, but odds are pretty good that applying these self-consistent cal curves will reduce the v2 data to be about 1.5.
Monday, August 22, 2011
Bolocat v1-v2 comparison
For this experiment, I ran Bolocat on all of the v1 and v2 images using the source masks Erik derived for v1. I then compared the derived fluxes using both aperture photometry (as defined in bolocat) and the mask sums.
First, note that the object_photometry code Erik wrote does NOT do background subtraction - this is important for understanding non-multiplicative offsets between v1 and v2.
I fit a 2-parameter model (a line) to the v2 vs v1 plots using two methods. The simple linear-least-squares method is one we're all familiar with, and it gives semi-reasonable results, but is NOT statistically robust when there are errors on both axes. The other fit method used was Total Least Squares, which is approximately equivalent to Principle Component Analysis with 2 vectors. It uses components of the singular-value-decomposition to determine the best fit. The fits returned by TLS should be more robust, though the additive offsets need not be.
Conclusion: Our factor of 1.5 looks like it was pretty accurate. For 40" apertures, the best fit is ~1.56, which is easily within the error bars. Luckily, for 40" apertures, there is no apparent need for an additive offset (I'm pretty sure the uncertainty on the measured offset is larger than the offset, though statistically that is not the case), which would complicate things.
However, for the source mask, there is a greater scaling factor and a very substantial offset. This implies that the peaks in v2 are brighter by a large factor, but the backgrounds in v2 are actually lower than in v1 (though please do check my reasoning here). I'm really not sure what to make of the difference between source mask and aperture yet, though... there's probably something significant in the source mask being forced to pick positive pixels. (and peppered pickles)
First, note that the object_photometry code Erik wrote does NOT do background subtraction - this is important for understanding non-multiplicative offsets between v1 and v2.
I fit a 2-parameter model (a line) to the v2 vs v1 plots using two methods. The simple linear-least-squares method is one we're all familiar with, and it gives semi-reasonable results, but is NOT statistically robust when there are errors on both axes. The other fit method used was Total Least Squares, which is approximately equivalent to Principle Component Analysis with 2 vectors. It uses components of the singular-value-decomposition to determine the best fit. The fits returned by TLS should be more robust, though the additive offsets need not be.
Conclusion: Our factor of 1.5 looks like it was pretty accurate. For 40" apertures, the best fit is ~1.56, which is easily within the error bars. Luckily, for 40" apertures, there is no apparent need for an additive offset (I'm pretty sure the uncertainty on the measured offset is larger than the offset, though statistically that is not the case), which would complicate things.
However, for the source mask, there is a greater scaling factor and a very substantial offset. This implies that the peaks in v2 are brighter by a large factor, but the backgrounds in v2 are actually lower than in v1 (though please do check my reasoning here). I'm really not sure what to make of the difference between source mask and aperture yet, though... there's probably something significant in the source mask being forced to pick positive pixels. (and peppered pickles)
Subscribe to:
Posts (Atom)
Categories
- administrative
- alignment
- analysis
- aperture photometry
- artifacts
- bolocat
- calibration
- cleaning
- cvs
- data release
- deconvolution
- deline
- discrepancy
- distortion mapping
- documentation
- downsampling
- errors
- flagging
- iterating
- mapping
- maps
- methods paper
- minor
- perseus
- pipeline
- planning
- plots
- point source
- pointing
- problems
- projection
- publications
- simulation
- team
- testing
- v2.0
- version comparison
- weighting















































